Subject: Nitrile gloves
Further testing of chlorinated nitrile glove samples has indicated that the corrosion exhibited during accelerated corrosion tests is caused by an excess of a sulfur based neutralizing agent used during the chlorination process. The sulfur based compound can easily be detected by the sodium azide test described by Daniels and Ward (Studies in Conservation, vol. 27, nr. 2, May 1982, pp. 58-60.). Will Jeffers Collections Care Scientific Research Assistant Scientific Research Laboratory Museum of Fine Arts 465 Huntington Avenue Boston, MA 02115 5597 617-369-3466 Fax: 617-369-3702 *** Conservation DistList Instance 17:24 Distributed: Tuesday, August 26, 2003 Message Id: cdl-17-24-002 ***Received on Monday, 25 August, 2003