JAIC 2004, Volume 43, Number 3, Article 4 (pp. 255 to 272)
JAIC online
Journal of the American Institute for Conservation
JAIC 2004, Volume 43, Number 3, Article 4 (pp. 255 to 272)

ENGINEERING PROPERTIES OF HISTORIC BRICK: VARIABILITY CONSIDERATIONS AS A FUNCTION OF STATIONARY VERSUS NONSTATIONARY KILN TYPES

DEBRA F. LAEFER, JUSTIN BOGGS, & NICOLE COOPER

ABSTRACT—Brick produced prior to the mid-20th century exhibit high levels of variability in appearance, geometry, and mechanical properties. Understanding historic brick variability is important for accurate performance prediction of existing structures and for the selection of appropriate replacement units. A lack of uniformity among historic brick can be caused by molding and firing methods as well as the composition of their raw materials. This article focuses on one aspect of production-induced disparities: kiln type. Specifically, the distinctions between products from stationary and nonstationary kilns are compared through historic data and recent laboratory tests. Tremendous variance can be shown between both kiln types and even within a single firing for stationary kilns. Although kilns of past eras were constantly improved for energy efficiency, their products continued to be highly inconsistent in appearance and performance until the introduction of nonstationary kilns. This article presents the mechanics of heat distribution in kilns and demonstrates its direct impact on the variability of engineering properties due to inconsistent heat application. Laboratory results of pre–Civil War brick and modern brick are presented to illustrate the range of results and the level of variability for unit weight, compressive strength, and absorption.

TITRE—Propri�t�s physiques des briques anciennes: taux de variabilit� en fonction des fours de cuisson stationnaires ou mobiles. R�SUM�—Les briques fabriqu�es avant le milieu du 20e si�cle varient consid�rablement de par leur apparence, g�om�trie et propri�t�s m�caniques. Une meilleure compr�hension du degr� de variabilit� pr�sent dans les briques anciennes permet de pr�dire avec plus de pr�cision la performance des structures existantes et un choix plus appropri� des mat�riaux de remplacement. Le manque d'uniformit� des briques anciennes peut �tre d� aux pratiques de moulage et de cuisson ou � la composition des mati�res premi�res. Cet article fait le point sur l'une des causes de la variabilit� des briques: le type de four de cuisson. En particulier, des briques cuites dans un four stationnaire et d'autres qui l'ont �t� dans un four mobile sont compar�es en terme de certaines donn�es historiques et aussi par divers tests scientifiques. Cette �tude indique des diff�rences importantes entre les briques selon le type de four utilis�; de plus, des briques cuites ensemble dans le m�me four stationnaire peuvent aussi varier �norm�ment entre elles. De par les �poques, les fours furent constamment am�lior�s dans le but de les rendre plus efficaces �nergiquement, mais les briques produites continuaient � poss�der des propri�t�s et apparences tr�s variables jusqu'� ce que le four mobile soit invent�. Cet article pr�sente les m�canismes de distribution de la chaleur � l'int�rieur d'un four et illustre comment une application non-constante de la chaleur r�sulte en une grande variabilit� dans les propri�t�s physiques des briques. Les r�sultats de tests en laboratoire effectu�s sur des briques datant d'avant la Guerre de S�cession et d'autres d'origine moderne sont pr�sent�s et d�montrent leur taux de variabilit�, en particulier en ce qui a trait � leur r�sistance � la compression, leur poids unitaire et leur degr� d'absorption.

TITULO—Las propiedades mec�nicas del ladrillo hist�rico: consideraciones con respecto a la variabilidad como funci�n del horno estacionario comparado con el horno continuo. RESUMEN—El ladrillo producido durante la primera mitad del S XX muestra altos niveles de variabilidad en apariencia, geometr�a y propiedades mec�nicas. El entender la variabilidad del ladrillo hist�rico es importante para la predicci�n acertada del comportamiento de las estructuras existentes y para la selecci�n de unidades apropiadas de reemplazo. La carencia de uniformidad en el ladrillo hist�rico puede ser el resultado de los sistemas utilizados para moldearlo y para hornearlo tanto como de la composici�n de la materia prima. Este articulo trata un aspecto de las diferencias causadas durante la producci�n: el tipo de horno. Espec�ficamente la diferencia entre los ladrillos producidos en hornos estacionarios y en hornos continuos son comparadas por medio de datos hist�ricos y pruebas de laboratorio recientes. Grandes variaciones son visibles entre ambos tipos de horno, y a�n dentro de una hornada de un horno estacionario. A pesar de que los hornos en �pocas antiguas eran constantemente mejorados para incrementar su eficiencia en el uso de energ�a, los productos continuaban siendo muy inconsistentes en apariencia y comportamiento hasta la introducci�n de los hornos continuos. Este art�culo presenta la mec�nica de la distribuci�n del calor en los hornos y demuestra el impacto directo en la variabilidad de las propiedades mec�nicas causadas por la aplicaci�n de calor en forma inconsistente. Resultados de laboratorio en ladrillos anteriores a la Guerra Civil (de los EE UU) y ladrillos modernos se presentas con respecto al rango de resultados y el nivel de variabilidad en fuerza de compresi�n, peso por unidad y absorci�n.

TITULO—Propriedades mec�nicas de tijolo hist�rico: considera��es sobre a variabilidade em fun��o dos tipos de forno estacion�rio versus forno n�o-estacion�rio. RESUMO—Os tijolos fabricados at� meados do s�culo XX apresentam grandes varia��es na apar�ncia, geometria e nas propriedades mec�nicas. Entender a variabilidade de tijolos hist�ricos � importante para uma an�lise precisa do comportamento de estruturas existentes e para a escolha de elementos de substitui��o apropriados. A falta de uniformidade entre os tijolos hist�ricos pode ter origem nos m�todos usados na moldagem e na cozedura, bem como, na composi��o das suas mat�rias-primas. Este artigo aborda um dos aspectos da desigualdade da produ��o induzida: o tipo de forno. Mais especificamente, as diferen�as entre os produtos obtidos nos fornos estacion�rios e n�o-estacion�rios s�o comparados atrav�s de dados hist�ricos e recentes testes de laborat�rio. Varia��es significativas podem ser constatadas entre os produtos em ambos os tipos de forno e at� em uma mesma cozedura em fornos estacion�rios. Embora os fornos de �pocas passadas tivessem sido continuamente melhorados visando a efici�ncia da energia, os seus produtos continuaram a ser muito inconstantes em apar�ncia e desempenho at� a introdu��o dos fornos n�o-estacion�rios. Este artigo descreve o mecanismo da distribui��o de calor nos fornos e demonstra o seu impacto directo na varia��o das propriedades mec�nicas dos tijolos devido � aplica��o inconsistente de calor. S�o apresentadas an�lises de laborat�rio realizadas em tijolos fabricados anteriormente � Guerra Civil Americana e em tijolos modernos, referentes tanto a gama de resultados obtidos quanto ao n�vel de variabilidade das for�as de compress�o, peso unit�rio e absor��o.


1 INTRODUCTION

Performance characteristics of an individual brick are fundamentally important both when attempting to predict the behavior of existing buildings and to select replacement units for such structures. For the modern design professional working with historic structures, performance variability in materials is a largely unfa-miliar concept. That unfamiliarity makes behavioral prediction extremely difficult, yet prediction is critical because of limitations and prohibitions on the extensive destructive testing that would be necessary to fully assess the masonry performance of an existing structure. For historic structures, variability in masonry performance tends to be extremely high compared to expectations for modern materials. Increasingly, the critical issue is picking input parameters to generate accurate computer modeling. By overpredicting capabilities, the risk to a structure from man-made or natural phenomena, especially ground movements such as tunneling, excavation, and earthquakes, may not be fully assessed; the resulting recommendation for no intervention can unnecessarily endanger the building. By underpredicting capabilities, limited resources may be unnecessarily expended to protect a structure that is competent to withstand potential ground movements without any intervention around the site or to the structures themselves.

Even without taking into consideration the additional complications of age-and weather-based deterioration, the prediction of masonry performance is highly complex. Masonry variability is a function of brick and mortar properties and the bonding between them. Even by considering only the historic brick (ignoring mortar-and bonding-related issues), extensive differences can be seen in physical appearance (e.g., color, geometry, surface texture) and engineering properties (e.g., compressive strength, hardness, and absorption), and these differences can significantly impact the performance of masonry structures. Variability in historic brick is owing to the raw materials used as well as to the methods by which the brick were produced. Brick performance is a function of the clay type and processing as well as the molding, drying, and firing of the brick. This article concentrates on initial brick variability as a function of differences in firing technology. The firing process can profoundly influence the nature and performance of a masonry unit. To highlight performance differences as a function of the firing process, historic brick and brick replicated to match historic material are compared to modern material both through the presentation of historic data and through recent laboratory tests.


2 ENGINEERING PROPERTIES

An evaluation of masonry studies from the early 20th century and more recent research related to replicated historic brick indicate that kiln selection is a major cause of historic brick's inconsistent engineering properties. Tests of early 20th-century brick clearly document substantial variability in compression, tension, and absorption. Brick data from four parts of the United States (Chicago, Detroit, Mississippi, and New England), from as recently as 1929, display a large amount of scatter across a wide variety of engineering properties (table 1). Compressive strengths ranged from 19,375 kN/m2 to 71,019 kN/m2, tensile strengths from 1,531 kN/m2 to 4,144 kN/m2, bending strengths from 4,358 kN/m2 to 10,136 kN/m2, and shear strengths from 7,585 kN/m2 to 24,477 kN/m2 (Stang et al. 1929).

In a separate 1929 study, McBurney's testing of more than 500 brick representing 27 manufacturers demonstrated that specimen behavior is influenced

Table . Comparative Brick Testing from Stationary Kiln
by method of manufacturing, type of raw materials, lamination characteristics, cracks, nodules, black cores, other inclusions, texture (e.g., granular, glassy), and degree of firing (table 2) (McBurney 1929). Given the extensive variability of the product from a single kiln, manufacturers often offered as many as four or five grades of brick (best, first, second, and third class, and clinkers) (Keele 1908). Clinkers were overfired brick, and salmons were underfired ones, so called because of their light coloration. These defective brick were often sold for nonstructural purposes due to their relatively poor strength characteristics, although their compressive strengths generally exceeded modern ASTM requirements.

The high level of performance variability of historic material stands in strong contrast to modern expectations and experience. Modern standards cate-gorize brick into one of three weathering grades (severe, moderate, or negligible). For each, minimum performance standards are set for strength (table 3) (ASTM 2004). According to this standard, five randomly selected brick must exhibit a minimum compressive strength of 20,685, 17,238, and 10,343 kN/m2 for the severe, moderate, and negligible grades, respectively (ASTM 2004). There are similar, slightly less rigorous standards for any individual brick, which include absorption and saturation limits (table 3). ASTM C62 also limits dimensional variations by specifying the maximum amount of variation from the standard dimensions (e.g., 5 mm in any direction for a 76–102 mm wide brick) (ASTM 2004). Extensive testing by Subasic and Borchelt (1993) on modern materials show performance capabilities far in excess of these minimum requirements, with an average compressive strength of 12,040 kN/m2 and an average 24 hour cold absorption of 5.4% (weight/weight).

Modern performance prediction of historic material is difficult because of the wide range of performance possibilities and the poor correlation between various performance indicators. Among 13 engineering properties tested by Stang and associates (1929), there was an average 287% difference between the low and high results (based upon 4 to 10 specimens per brick type), with poor correlation, if any, between brick types (see table 1). Work by McBurney (1929) on more than 40 designations of brick demonstrated no relationship between compressive strength and modulus of rupture or among testing orientations (i.e., flat, edge, and end) (see table 2); because of modern manufacturing standardization for present-day brick, such variability would no longer be in evidence. Given the potential for nearly an order of magnitude difference in various engineering properties across various historic brick, identification of proper prototype values for historic materials remains a major challenge (Laefer 2001). Value selection for compressive brick strength is of particular importance, as it is a required input variable for determining overall masonry strength (MSJC 2002).

Since unit compressive strength is known to have an inverse relationship with absorption (table 4) and a direct correlation with firing temperature, an investigation into the application of heat in various firing methods and equipment will help form realistic expectations regarding the anticipated range of performance values.


3 KILN TYPES

Dimensional and behavioral variability in brick can be considered a direct outcome of the firing process, which is highly dependent upon kiln type. Kilns have traditionally been distinguished by fuel type, efficiency and position of their heat source, heat distribution, and heat continuity. To demonstrate how the technology has changed along with the resulting products produced, examples of stationary periodic updraft and downdraft and stationary continuous draft kilns and their affiliate products are compared to nonstationary tunnel kilns, where the term “station-ary” reflects the position of the brick within the kiln.

The major initial evolution is how the heat is distributed from a single source or group of sources across the kiln. The distribution begins as a localized and stationary process and eventually becomes not only relatively well distributed through the firing chamber but mobile between a series of firing chambers. The second and more important change in terms of engineering properties for brick is how in the 20th century the brick is changed from being a stationary element

Table . Properties of 30 Brick Types Tested at Various Orientations
within the kiln to a nonstationary element as it is placed on tracks and propelled through a series of firing and cooling chambers. The terms “stationary” and “nonstationary” thus refer to the permanence of position of the elements being fired. Until the 20th century, all kilns were stationary. Tracing the evolution of stationary kilns from updraft to downdraft to continuous draft provides the basis for the development of the nonstationary tunnel kilns.


3.1 UPDRAFT

Updraft kilns date back to the ancient Greeks and have remained relatively unchanged in their basic features to the present (Rhodes 1981). Updraft kilns incorporate an enclosure in which to house the brick, lower apertures to insert fuel, and a chimney mechanism up above. A primitive but popular variant was the scove kiln, also known as a field kiln. Used extensively in the 18th century, with limited continued usage in the 20th (Conner 1910; Ritchie 1960), this temporary kiln was constructed out of raw brick that were fired as part of the overall process. Thus some of the brick that were fired were stacked to form the outside structure of the kiln (fig. 1), and some of the raw clay units were an inherent part of the firing apparatus (Rhodes 1981). The brick were placed in mounds, creating the appearance of a long rectangle with slightly slanted sides, and were strategically stacked to allow the flames and heat to access different sections of the mound via “passage-ways” (McKee 1973). The outer brick, prior to firing, were covered with a layer of clay and grass to allow venting of the vapors. In a single firing 40,000–50,000 brick could be fired.

Table . Physical Requirements of Modern Brick

Table . Compressive Strength as an Inverse of Absorption Capacity from Unknown Kiln Type

Fig. 1. Scove kiln (Rhodes 1981, 69)

For scove kilns, initially brush, and then coal, was used as fuel (Rhodes 1981). The fires were fed and stoked for a week, and then the fire holes were covered with brick and mortar to prevent the heat from escaping. During this period the fires burned out, but the greater portion of the heat remained. While the kiln remained closed, the heat was allowed to dissipate for approximately one week.

During the firing, brick were exposed to varying temperatures up to 982�C, resulting in very inconsistent strengths (Rhodes 1981). Brick close to the fires were overfired and sometimes vitrified, while brick far from the flames were softer and often more porous, causing them to be less desirable because of their lower strengths.

Replication of historic material has also shown highly variable performance. Quarter-scale, extruded clay units were fired in a permanent, updraft kiln located in the University of Illinois Ceramics Engineering Department (Laefer 2001). The brick were dried for a minimum of 24 hours at 66�C. The units were fired in a stationary (porcelain) kiln with electrical heating elements on five sides (fig. 2). The brick were placed in two masses, each 464 mm by 597 mm by 127 mm high, containing approximately 1,400 brick per firing. Approximately 25,000 brick were fired in more than a dozen firings. Firing occurred at 496�C (verified by a no. 09 Orton cone) for at least 12 hours, with an additional day of kiln time for cooling.

The goal was to create high-absorption, low-strength brick, typical of low firing. Since the power source was electrical (as opposed to gas or coal), the oxidizing (as opposed to reducing) atmosphere facilitated a rough correlation among coloration and brick absorption and strength, with the darker color being indicative of less absorptive and stronger brick; as the temperature increased, the iron oxide within the clay reacted and exhibited color change (tables 5, 6). Using a Munsell Color Chart, the brick were designated into categories and sorted according to color (see table 5). The designation numbers for the fired brick ranged from 1 to 5, with 1 being lightly fired and 5 most fired. The darker the brick, the less absorptive and stronger it was (see table 6). The designations were selected based on color distinctions that were consistently, visually identifiable by the student research assistants (Laefer 2001). During the sorting of the 25,000 miniature brick, many brick were found to have a bifurcation, where one half was of one designation and the other half another. Thus some brick are listed with a hyphenated number.

Fig. 2. Electric updraft kiln with miniature brick

Table . Munsell Color Chart Description of Brick to Depict Brick Designation for Miniature Replica Brick in Stationary Kiln

The results of two firings demonstrated the variability both within a single firing and between firings that will occur, even under highly controlled procedures using Orton cones and timed firings (fig. 3) (Laefer 2001); as this brick manufacturing was done for a larger research project with other objectives, the brick of designation 2 and 3 were combined because their compressive strengths fell within the target range for the overall testing program. The variability from a single firing exhibited over 100% strength difference between the strongest and the weakest brick. Although higher temperature firing or firings for longer periods of time would result in less variability, as well as a stronger product, the larger mass of brick needs to be considered since such comparative data are not fully available. The data presented here may be considered qualitatively although not quantitatively indicative. These model brick were also compared to a similar miniature product produced in a modern tunnel kiln, which resulted in a profoundly different product (designated by the number 20) that achieved strengths nearly five times greater than any of the lightly fired products (fig. 4).

Despite wide variability of the final product, the scove kiln was popular and commonly used because it did not require the construction of a permanent facility (Rhodes 1981). The relative ease of constructability and mobility allowed the temporary placement of these kilns at the point of use, instead of miles away from the construction site, where transportation would have posed economic and logistical impediments. Scove kilns are known to have been used in the construction of the College of William and Mary, and remains of seven of these temporary kilns have been found in Williamsburg, Virginia (McKee 1973).

Table . Absorption by Coloration for Miniature Replica Brick in Stationary Kiln


3.2 DOWNDRAFT

A more refined version of a draft kiln with better heat distribution was the downdraft kiln, which was especially well suited to burning smaller quantities of higher-grade fuel (Hoehne 1910) and accommodating large quantities of brick (50,000–60,000). The brick were placed in stacks, with narrow spaces between them, to allow the heat to pass around the stacks (BIA 2004); a photograph of the interior of a downdraft kiln can be seen in figure 5. The down-draft kiln incorporated a multitude of evenly spaced fireplaces and a flue beneath the kiln floor. The flames were initially directed upward, and then the heat was drawn downward from the top to fire the brick. The heat was collected by flues, which led to an externally placed chimney. This method promoted a more consistent heat exposure to all brick than the scove kilns, but it still lacked a high level of uniformity in the heat distribution and, thus, in the final product. Similar to the product of scove kilns, a significant portion of downdraft kiln brick were excessively porous and soft (HCF 2002).

A popular example of a downdraft kiln dating back to the 17th century was the beehive kiln, which was round and, thus, derived its name from the beehive it resembled (figs. 6, 7). The kiln was made of mortar and previously fired brick, and the dome was wrapped with steel bands to accommodate heat expansion (see fig. 6). The fuel was introduced through side portals at specific points around the circumference of the kiln (see fig. 7). The fire was partitioned from the raw clay units by low wall enclosures (see fig. 5).

Even from within one downdraft kiln and across one firing, brick strength and density properties vary, depending on brick position within the kiln. Compressive strength and density tests were conducted in 1907 on brick sampled from various positions (top, one-third height from the top, one-third height from the bottom, and the bottom) within a single kiln firing (table 7). Data from both mud brick and dry-pressed brick from 1907 exhibit a trend of increasing brick strength and density with proximity to the heat source, despite the brick's being formed by two different molding processes. The

Fig. 3. Brick distribution of two firings of replica brick as sorted by brick designation as related to strengths in table 5 and figure 4 (Laefer 2001)
Fig. 4. Average ultimate compressive strength of various levels of brick firing for replica brick fired in stationary kiln
results clearly confirm the location of the heat source as the top of the kiln as well as the potential for a large range of final products. Many of the beehive kilns were closed in the United States in the 1960s because they could not economically be converted from coal consumption.

Fig. 5. Brick stacks inside a downdraft, beehive kiln; heat enclosure visible (Laefer 2001, 641)


3.3 CONTINUOUS DRAFT

Initially used in the first century A.D., chamber kilns are typified by multiple firing sectors within a single kiln. From the beginning, they were extremely fuel efficient because the excess heat from one chamber was transferred to another chamber through the use of flues, thereby minimizing heat wastage. These kilns were widely used until the mid-19th century, at which time the continuous chamber kiln was developed (Rhodes 1981). The continuous chamber kiln invented by Friedrich Hoffman and A. Licht in 1858 was a refinement of the previous design and consisted of a series of single-chamber kilns adjoined to each other. Each chamber is fired sequentially throughout the multipart kiln, and the process of firing, cooling, and brick loading occurs progressively through the series of chambers. Unused heat from one chamber is transferred to the next for preheating (fig. 8). To prevent interruptions in this cycle of preheating, firing, and cooling, the kilns were placed in a circular manner, resulting in a reduction of fuel consumption by two-thirds (Roberts 1962). Stang and associates' 1929 study demonstrated a wide range of brick performance. Based on their manufacturing date, the brick were probably products of a continuous chamber kiln (see table 1), as Hoehne (1910) estimated that by 1910 90–95% of all brick kilns in Europe were continuous chamber kilns and that the trend toward their dominance was beginning in the United States. The original circular chamber design (see fig. 8) was first modified by Hoffman in 1870 to decrease

Fig. 6. Exterior of beehive kiln (Laefer 2001, 641)
product variability caused by the nonuniform geometry of the original design. Hoffman's modification of the circular design was to use two long tunnels connected by curved end sections (Roberts 1962). Visually, this design is clearly a predecessor for the tunnel kiln.

Fig. 7. Plan view of downdraft, beehive kiln


3.4 TUNNEL KILN

The tunnel kiln is similar to the chamber kiln in its continuous application of heat, but differs because it is substantially more heat efficient and because the brick, instead of the heat, move through the kiln. In a tunnel kiln the heat source remains stationary while the brick travel, facilitating mass production and minimizing maintenance costs because the stress on the kiln is reduced (fig. 9). Previous kilns underwent cycles of heating and cooling, which induced cyclical strains in the kiln structure. In contrast, the only portion of the tunnel kiln that is heated remains so continuously (Norton 1957); therefore the heat-based cyclic straining does not occur.

Although the first tunnel kiln was built in 1751 in France, these types were not widespread until the late 1800s in England, with O. Bock's innovation in sand seals (fig. 10). Previously, poor seals between the actual cars and the firing chambers failed to insulate the cars' mechanisms from the extreme heat of the fire (Rhodes 1981). The top of Bock's new seal mechanism was made of a refractory material sufficiently thick to protect the metal. Along each side of the kiln walls was a trough filled with sand. A steel blade attached to the cart dipped into the sand trough, creating a highly efficient, gas-tight seal, which is a trademark of modern tunnel kilns (Norton 1957). The earliest tunnel kilns operated in a manner similar to modern kilns in that the brick passed though three stages: preheating, firing, and cooling. The brick were placed on cars that ran on a track through a tunnel adjacent to the heat source. Throughout their preheating cycle, the brick were

Table . Downdraft Kiln Brick Properties as a Function of Kiln Position
subjected to increasing temperatures until the firing cycle, where a maximum temperature of 1066�C was reached and maintained (Rhodes 1981).

Fig. 8. Circular placement of separate kilns in a chamber kiln system (adapted from Rhodes 1981, 80)

As part of the normal 36 hour trip from entering the kiln to exiting it, the brick next passed through the cooling stage. The cooler air entered the end of the tunnel via a blower and was collected at the end of the firing zone. Similar to the draft kilns, the dissi-pating heat from the firing cycle was blown to the beginning of the tunnel for the preheating portion (fig. 11) (Norton 1957). Slow cooling was introduced to reduce cracking and pitting, which could ultimately induce strength loss (BIA 2004).

The difference between the modern and early tunnel kiln is the use of blowers for both preheating and cooling. Ducts and blowers promote a more uniform distribution of the heat in the drying, preheating, firing, and cooling cycles (Rhodes 1981). Another reason for improved consistency in later tunnel kilns was the fuel source. Early versions of these tunnel kilns, including Bock's, continued to rely on combustion fuels, such as coal, which had to be continuously fed. When oil and gas burners were introduced (ca. 1900 and ca. 1920, respectively) (Rhodes 1981), the tunnel kilns became more economical and produced a more uniform product because they were less reliant on human tending of the fuel (fig. 12).

Since the brick in a tunnel kiln are more uniformly exposed to the same heat treatment throughout the tunnel kiln, there is a much higher level of uniformity in the final product. Furthermore, the actual temperature could then be sustained at a higher temperature (nearly 1093�C versus the typical 538�C found in direct draft kilns) and automatically controlled by computers that continuously monitor and adjust the temperature at various stages of the process and change the speed at which the brick pass through the kiln (BIA 2004).

Fig. 9. Modern tunnel kiln (GGB 2003)

Fig. 10. Cross section of tunnel kiln (adapted from Rhodes 1981, 81)

To better understand the impact of kilns on the engineering properties of brick, modern shale units were tested by the authors alongside two highly distinctive sets of pre–Civil War brick. The pre–Civil War brick were salvaged from the demolished Jakes house in Urbana, Illinois, in 2000 (one of the few buildings that predated the Civil War–era railroad through the city) and from the extant main house at Somerset Place, a plantation in eastern North Carolina that most likely dates from 1830 or shortly thereafter. The modern units were fired in a tunnel kiln and obtained randomly from a local supplier in the Raleigh, North Carolina, area from a palette of brick provided for a separate research project. Brick from the pre–Civil War structures were randomly gathered from the project sites. The specific kiln type for the pre–Civil War brick is not known from written records or archaeological remains, but in both cases it is thought to have been fairly primitive because of low compressive strengths and the orange color of the brick, both of which are indicators of low firing temperatures.

Nine of each brick type were compression tested as full units: three flat, three on edge, and three on end. The use of all three orientations provide data that would have been more typical of that collected in the 19th century, when the flat testing of a half-brick had not emerged as standard procedure. Absorption testing was done in buckets of cold water for up to 30 minutes or until the brick stopped expelling air to prevent material slaking of brick that were not fully vitrified. Figure 13 plots the unit weight of each brick versus the percentage of absorption as a function of weight over weight. Two distinctive trends emerge:(1) the lighter the unit weight of the brick, the less absorptive it is; and (2) pre–Civil War brick have an extremely broad range of possible unit weights (even within a single project) compared to modern brick. The full results of all the testing are listed in table 8, which emphasizes the relative variability of the pre–Civil War material in all of its engineering properties (e.g., unit weight, compressive strength, and absorption). The unit weight of modern brick was more than twice that of the historic brick and had a coefficient of variation an order of magnitude less than the Jakes house brick and half that for the Somerset Place brick. The consistency of the modern product is most clearly visible in examination of the unit weight (see fig. 13), which is a direct result of the higher firing levels achieved in the tunnel kilns.

Fig. 11. Modern tunnel kiln (adapted from Rhodes 1981, 81)

Fig. 12. Timeline of kiln development

Fig. 13. Absorption versus unit weight of modern brick compared to pre–Civil War brick

The maximum compressive strength of the modern units were on average double that of those from the Jakes house and an order of magnitude greater than those from Somerset Place. The coefficient of variation for the modern brick was half that from Somerset Place and a quarter that from the Jakes house, showing much greater consistency in product in the modern materials. These results were fairly consistent regardless of the orientation of the brick during compression testing.

Absorption results were similar in that the modern brick absorbed only a third of the water absorbed by the historic material, but in this case the coefficient of variation for the absorption was nearly as great in the modern material compared to the Jakes house brick and substantially exceeded that of the Somerset Place brick. An alternative method of considering the data is presented in figure 14, where the unit weight is plotted against the compressive strength, but each sample is represented graphically as a function of its absorption level. The size of the circle proportionally shows the brick's relative capacity for absorption. What the figure emphasizes is that although a direct correlation cannot be made between the compressive strength (in any of the testing orientations) and the unit weight or the absorption level, a strong trend is in evidence. What is also interesting to note is that historic brick with unit weights similar to modern material performed at levels equivalent to modern materials, but that these samples were only a fraction of the strength of the modern brick that was tested.

Working with material that has experienced 150 years of exposure raises questions as to the impact of age and weather-based deterioration. The topic has been extensively studied elsewhere (see the following references for a sampling of available research: Berra et al. 1993; Bonnell and Pippard 1952; Honeyborne 1990; Hueck-van der Plas 1968; Morton et al. 1990; Sabbioni et al. 1993) and can be considered largely outside the scope of this article since control units were not available to accurately quantify any negative influences of decades of exposure. But a reexamination of figure 14 provides some insight. Unlike a destructive compressive strength test, determination of unit weight can be considered as an inherent brick property. If age or weather removes part of the material, the total weight changes, but the unit weight is unaffected as it represents the existing weight over the existing volume. Unit weight may be considered as an inherent indicator of brick capacity. Such consideration requires additional exploration of historic material, as the limited sample set and restricted access to historic material do not permit more precise correlations or conclusions.


4 CONCLUSIONS

Variation in the appearance and engineering properties of historic brick is a direct reflection of quantity and distribution of heat within a kiln. The high level of variability in historical materials may be unanticipated by modern professionals schooled in the production techniques of 20th-century tunnel kilns, but knowledge of probable variability is critical for all individuals working in and around historic masonry structures, because establishing structural performance levels through extensive testing would be both potentially destructive and inconclusive. Although 19th-century brick could and did regularly achieve modern brick strengths, as well as minimum strength standards, a much wider performance range should be expected for historic units. Such understanding is critical when selecting input values for material properties for computer modeling. A sampling of two types of pre–Civil War brick from stationary kilns compared to modern brick from a nonstationary kiln demonstrated that the historic materials had lower average strengths, lighter unit weights, and higher absorption levels, as well as higher variability levels of those properties, particularly related to strength and unit weight, where the difference ranged from twice the level to an entire order of magnitude greater in the variability of historic materials than for the modern brick that was produced in the more consistent and controllable nonstationary kilns. As such, the results of selective, limited brick testing from historic structures should be used with great care when choosing engineering properties for analytical input, computer modeling, or material replacement specification for structures that were constructed from brick from stationary kilns.

Table . Comparative Test Results of Modern and Pre–Civil War Brick

Fig. 14. Compressive strength versus unit weight of modern brick compared to pre–Civil War brick



REFERENCES

ASTM. 2003. Standard test materials for sampling and testing brick and structural clay tile, C67-03a. Philadelphia: American Society for Testing and Materials.

ASTM. 2004. Standard specification for building brick (solid masonry units made from clay or shale), C62-04. Philadelphia: American Society for Testing and Materials.

Berra, M., L.Binda, A.Fatticcioni, and T.Squarcina. 1993. Laboratory and in-situ measurement procedure of the decay of masonry surfaces. In Sixth International Conference on Durability of Building Materials and Components in Omiya, Japan. London: Taylor & Francis Books. 2:834–43.

BIA2004. Brick Industry Association. www.bia.org/BIA/technotes/technote.htm (accessed April 18, 2004).

Bonnell, D. G. R., and W. R.Pippard. 1952. Some common defects in brickwork. National Building Studies Bulletin 9. London: Department of Scientific and Industrial Research, Building Research Station, HMSO.

Brickbuilder. 1907. Strength of brick and brick piers. Brickbuilder16(4) (April):62–65.

Conner, E.1910. The French brick trade. Clay Record37(4) (August):18–19.

Fried, A. N., and D. W.Law. 1995. Factors influencing masonry flexural strength. Proceedings of the British Masonry Society7 (October):85–89.

GGB. 2003. Glen-Gery Brick. www.glengery.com/hanley/june (accessed April 18, 2004).

HCF.2002. Historic Charleston Foundation. www.historiccharleston.org/preservation/notebook.html (accessed April 18, 2004).

Hoehne, R.1910. The modern way of burning brick. Clay Record37(5) (September):21–22.

Honeyborne, D. B.1990. Weathering and decay of masonry. In Conservation of building and decorative stone, ed. J.Ashurst and F. G.Dimes. London: Butterworth-Heinemann. 1:153–84.

Hueck-van der Plas, E. H.1968. Micro-biological deterioration of porous building materials. International Biodeterioration Bulletin1:11–28.

Keele, J.1908. Brickwork masonry. Applied Science (incorporated with Transactions of the University of Toronto Engineering Society) 2(2):69–78.

Laefer, D.2001. Prediction and assessment of ground movement and building damage induced by adjacent excavation. Ph.D. diss., University of Illinois.

McBurney, J. W.1929. The compressive and transverse strength of brick. Journal of the American Ceramic Society12:217–29.

McKee, H. J.1973. Introduction to early American masonry stone, brick, mortar and plaster. Washington, D.C.: Preservation Press.

Morton, J., B. A.Richardson, and R. C.de Vekey. 1990. Deterioration of materials. In The maintenance of brick and stone masonry structures, ed. A. M.Sowden. New York: E. and F. N. Spon, an Imprint of Chapman Hall. 117–39.

MSJC. 2002. Specifications for masonry structures, ACI 530.1/ASCE 6/TMS 602. Farmington Hills, Mich.: Masonry Standards Joint Committee.

Norton, F. H.1957. Elements of ceramics. Reading, Mass.: Addison-Wesley.

Ritchie, T.1960. Early brick masonry along the St. Lawrence in Ontario. Division of Building Research Technical Paper 93. Ottawa, Canada: National Research Council. 115–22.

Rhodes, D.1981. Kilns: Design, construction and operation. 2nd ed. Radnor, Pa.: Chilton.

Roberts, J., ed. 1962. The science and art of brick-making. Part 1, The story of the brick: An historical survey. Clay Craft35(12) (September):414–17.

Sabbioni, C., G.Zappia, G.Gobbi, and M. G.Pauri. 1993. Deterioration of ancient and modern buildings due to environmental factors. Third International Conference on Structural Studies, Repairs and Maintenance of Historical Buildings at Bath, England: Structural Repair and Maintenance of Historical Buildings III,ed. C. A.Brebbia and R. J. B.Frewer. Boston: Computational Mechanics Publications. 235–42.

Stang, A. H., D. E.Parsons, and J. W.McBurney. 1929. Compressive strength of clay brick walls. Bureau of Standards Journal of Research3(108):507–71.

Subasic, C. A., and J. G.Borchelt. 1993. Clay and shale brick material properties: A statistical report. The Sixth North American Masonry Conference. Boulder, Colo.: Masonry Society. 1:283–94.


AUTHOR INFORMATION

DEBRA F. LAEFER earned her Ph.D. in civil engineering in 2001 from the University of Illinois at Urbana-Champaign, after attaining a B.A. in art history from Columbia University in 1991. She serves as the chair of the Heritage and Existing Structures Committee for the Earthquake Engineering Research Institute. She is an assistant professor of civil engineering at University College Dublin in Ireland and has been working in historic preservation since 1988. Address: Department of Civil Engineering, University College Dublin, Earlsfort Terrace, Room 115, Dublin 2, Ireland; 353-1-716-7276; fax: 353-1-716-7399; debra.laefer@ucd.ie

JUSTIN BOGGS and NICOLE COOPER are both research assistants in the Department of Civil, Construction, and Environmental Engineering at North Carolina State University and are former students of Dr. Laefer. Address for Boggs: Department of Civil Engineering, North Carolina State University, Campus Box 7908, Raleigh, N.C. 27695. Address for Cooper: 3003 Whitcomb St., Charlotte, N.C. 28269

Section Index