Subject: UV monitors
We've been using an International Light IL1400A that is quite reliable and portable. The only drawback with this meter is that it requires you to take a separate, simultaneous visible light reading and do a bit of calculation if you require a proportional reading (microwatts/lumen). Product information for the IL1400A can be found at <URL:http://www.intl-light.com/products/il1400a.html> Will Jeffers Collections Care Specialist Department of Scientific Research Museum of Fine Arts, Boston *** Conservation DistList Instance 13:38 Distributed: Wednesday, January 5, 2000 Message Id: cdl-13-38-010 ***Received on Tuesday, 4 January, 2000